X-ray Fluorescence Spectrometer for Sapphire Single Crystal

X-ray Fluorescence Spectrometer for Sapphire Single Crystal

 Solution Description
It can qualitative and quantitation analysis amongst different materials apart from factor C, also, the equipment can overall performance nicely in Mg,Al,Si,S,P, and Mn which other machine can not operate properly. It mainly utilized in the pursuing fields, this kind of as metal,  fireproofing, non-ferrous business, the good quality office, the plating thickness tests, ROSH inductor examination and so forth.
 Primary Attributes

(1).Accurate: Examination final results can be near to examination damp chemical methods.

(2).Rapid velocity: Testing massive amounts components in the sample only need to have couple of minutes.

(3).Non-reduction: It are unable to hurt the actual physical and chemical homes in sample.

(4).Visually: Investigation benefits are current directly in graph.

(five).CZPT: It can not pollute the environment.
 Main technical parameter

Analysis aspects Na-U,Mainly are Al,Si,P,S,K,Ca,Ti,V,Fe,Ni,Mn,Pb,Zn,Cu,Sn,Sb,As and so forth
examination assortment one ppm-99.ninety nine%
measuring time All the contents evaluation only in 1-2 minutes
analysis precision Standard deviation ≤0.08%
analysis error Up to the normal requirments
radiation dosage <25  μ sv/h
atmosphere temperature 15 ºC-35 ºC

 Main allocation

 Detection program

 Detector

 Type: electric powered refrigeration SDD detector

 Be window thickness: 50um

 The best resolution: 130eV

 CZPT response assortment: 1keV-50keV

X light-weight tube (for X ray spectrometer)

 Voltage: ~ 50kV

 Maximum recent: one.0mA

 Maximum electricity: 50W

 Filament voltage: two.0V

 Filament present: 1.7A

 Ray out angle: twelve °

 Target: Mo

 Be window thickness: .5mm

High-voltage electricity provide

 Input voltage: DC+24V ± ten%

 Input present: four.0A ( optimum )

 Output voltage: -5KV & 1mA

 Maximum electricity: 50W

 Voltage regulation price: .01% ( from no load to full load)

 Current adjustment rate: .01% ( from no load to complete load)

 Ripple element: .one% ( P-P benefit)

 The security of 8 hrs: .05%

 Vacuum pump

 Vacuum: vacuum test 20Pa restrict vacuum 2Pa

Optical integration design / method / vacuum cavity radiation safety

 X mild tube, detector, the composite filtertreatment technique, CCD, positioning program, computerized collimator switching method processor optical path are built-in in a closed composition, make certain the security of optical method with a shut optical path method as a vacuum cavity, by means of the loop and the maze effectively by utilizing X ray maximum energy at the very same time to guarantee the ray zero overflow.

Packing & CZPT



 

X-ray Fluorescence Spectrometer for Sapphire Single Crystal